Гордимся нашей репутацией

760103606, Кабель оптический LazrSPEED 300, 12 волокон ОМ3, LSZH, универсальный, гель, черный, фут

Артикул: 760103606
Цена по запросу Есть в наличии
Запросить цену СравнитьВ сравнении 
Доставка при оплате сегодня (28.03.2024): Москва: — Самовывоз: завтра — Курьером: 1 день Регионы РФ — ТК: 3-4 дня Оплата — Безналичный расчёт

Product Classification

Portfolio
CommScope
Product Type
Fiber indoor/outdoor cable
Regional Availability
Asia,Australia/New Zealand,EMEA,Latin America,North America

Standards And Qualifications

EN50575 CPR Cable EuroClass
Dca,s2,d1,a1
Cable Qualification Standards
ANSI/ICEA S-104-696,EN 187105,Telcordia GR-409

Representative Image

Click on image below to enlarge.

General Specifications

Construction Type
Non-armored
Cable Type
Stranded loose tube
Subunit Type
Gel-filled

Construction Materials

Fiber Type Solution
OM3, LazrSPEED 300
Total Fiber Count
12
Fiber Type
OM3, LazrSPEED 300
Fiber Type, quantity
12
Fibers per Subunit, quantity
12
Jacket Color
Black
Jacket UV Resistance
UV stabilized

Dimensions

Buffer Tube/Subunit Diameter
2.00 mm,0.08 in
Cable Weight
166.0 kg/km,112.0 lb/kft
Diameter Over Jacket
12.80 mm,0.50 in
Filler, quantity
5
Subunit, quantity
1

Physical Specifications

Minimum Bend Radius, loaded
19.6 cm,7.7 in
Minimum Bend Radius, unloaded
13.1 cm,5.2 in
Tensile Load, long term, maximum
1334 N,300 lbf
Tensile Load, short term, maximum
1000 lbf,4448 N
Vertical Rise, maximum
807.0 m,2647.6 ft

Flame Test Specifications

Flame Test Listing
NEC OFNR-LS ETL and c ETL
Flame Test Method
IEC 60332-3,IEC 60754-2,IEC 61034-2,IEEE 383,UL 1666,UL 1685

Environmental Specifications

Environmental Space
Aerial, lashed,Buried,Low Smoke Zero Halogen LSZH,Riser
Installation Temperature
-30 C to 60 C -22 F to 140 F
Operating Temperature
-40 C to 70 C -40 F to 158 F
Storage Temperature
-40 C to 75 C -40 F to 167 F

Mechanical Test Specifications

Compression
125 lb/in,22 N/mm
Compression Test Method
FOTP-41,IEC 60794-1 E3
Flex
35 cycles
Flex Test Method
FOTP-104,IEC 60794-1 E6
Impact
2.17 ft lb,2.94 N-m
Impact Test Method
FOTP-25,IEC 60794-1 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP-33,IEC 60794-1 E1
Twist
10 cycles
Twist Test Method
FOTP-85,IEC 60794-1 E7
Water Penentration
24 h
Water Penentration Test Method
FOTP-82,IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze
-2 C,28 F
Cable Freeze Test Method
FOTP-98,IEC 60794-1 F15
Drip
70 C,158 F
Drip Test Method
FOTP-81,IEC 60794-1 E14
Heat Age
-40 C to 85 C -40 F to 185 F
Heat Age Test Method
IEC 60794-1 F9
Low High Bend
-30 C to 60 C -22 F to 140 F
Low High Bend Test Method
FOTP-37,IEC 60794-1 E11
Temperature Cycle
-40 C to 70 C -40 F to 158 F
Temperature Cycle Test Method
FOTP-3,IEC 60794-1 F1
Яндекс.Метрика
Компания ООО "ЦЦК" 2024 | Политика конфиденциальности
Все цены указаны в рублях